Narrative Review: Parameter dalam Metode Analisis untuk Identifikasi Rhodamin B dalam Lipstik

  • Nurlita Dwi Putri Prihasti Universitas Singaperbangsa Karawang
  • Munir Alinu Mulki 1Program Studi Farmasi, Fakultas Ilmu Kesehatan Universitas Singaperbangsa Karawang
  • Muhammad Naufal Nurhadi Hidayat Program Studi Farmasi, Fakultas Ilmu Kesehatan, Universitas Singaperbangsa Karawang
Keywords: rhodamine B, lipstick, methods, parameters

Abstract

Rhodamine B is a synthetic dye used in the paper and textile industries, attracting attention due to its potential health hazards. It is used in various cosmetic products, although the Regulation of the Minister of Health of Indonesia No. 445/MENKES/PER/V/1998 prohibits its use in cosmetics due to risks of irritation, liver damage, and cancer. This article reviews the parameters of analytical methods for identifying Rhodamine B in lipstick. A narrative review was conducted using Google Scholar as a database over the past 10 years. The KLT method was found to be more widely used than HPLC or UV-Vis Spectrophotometry. Differences in Rf values in KLT are due to variations in the stationary phase. Parameter variations in HPLC system suitability tests are caused by operational conditions, sample conditions, and instrument performance. Analytical methods for identifying Rhodamine B in lipstick include KLT, HPLC/KCKT, and UV-Vis Spectrophotometry. It is concluded that each method has specific parameters that must be met: KLT is qualified if the Rf value comparison (standard vs. sample) is 0.2; HPLC/KCKT requires system suitability and validation tests; UV-Vis Spectrophotometry needs validation test parameters. KLT is preferred due to easy sample preparation and lower costs compared to HPLC and UV-Vis Spectrophotometry. It is recommended to consider necessary components when using these methods to maximize test results.

Downloads

Download data is not yet available.

References

Sulastina NA, Fitri M. Analisis Rhodamin B Pada Lipstik Yang Di Jual Di Beberapa Pasar Tradisional. Babul Ilmi J Ilm Multi Sci Kesehat. 2022;14(1):88–99.

PERMENKES RI. Peraturan Menteri Kesehatan Republik Indonesia Nomor:445/Menkes/Per/V/1998 Tentang Bahan Kosmetika dan Zat Warna Kosmetika. Dep Kesehat Republik Indones Jakarta. 1998;1–56.

Rambi EGS, Dorchichylhia Mangune G, Masontik R, Syalomitha Ceasaria Kaawoan G, Natanael Moningka G, Assa L. Review Artikel : Analisis Kandungan Berbahaya pada Lipstik yang Beredar di Masyarakat dengan Berbagai Metode. J Lentera Farma. 2023;66(1).

Putri DL, Pratiwi IE. BPOM Ungkap 181 Kosmetik Merkuri dan Non-merkuri 2023, Ini Daftarnya. Kompas.com [Internet]. 2023; Available from: https://www.kompas.com/tren/read/2023/12/11/081500565/bpom-ungkap-181-kosmetik-merkuri-dan-non-merkuri-2023-ini-daftarnya?page=all#page2

Masyulani F, Thristy I. Identifikasi Zat Pewarna Rhodamin B Pada Lipstik Yang Beredar Di Kalangan Mahasiswi Fakultas Kedokteran Universitas Muhammadiyah Sumatera Utara Angkatan 2013. Anat Med J. 2019;2(3):1–8.

Harmono HD. Validasi Metode Analisis Logam Merkuri (Hg) Terlarutn pada Air Permukaan dengan Automatic Mercury Analyzer. Indones J Lab. 2020;2(3):11.

Afriyeni H, Utari NW. Identifikasi zat warna rhodamin b pada lipstik berwarna merah yang beredar di pasar raya padang. J Farm Higea. 2016;8(1):59–64.

Adriani A, Andalia R, Rinaldi R, Ulya N. Analisa Zat Warna Rhodamin B Pada Lipstik Gloss Dan Matte Yang Dijual Dikota Banda Aceh Dengan Metode Kromatografi Lapis Tipis. J Pharm Sci. 2023;6(1):90–4.

Biasa A, Maarisit W, Pareta D, Lengkey KY. Analisis Rhodamin B Pada Lipstik Yang Beredar Di Pasar Lirung Kabupaten Kepulauan Talaud. Trop J Biopharm. 2021;4(1):53–7.

Jusnita N, Nandu LSS. Identifikasi Rhodamin B pada Sediaan Lipstik yang Beredar di Pasar Jakarta Utara dengan Metode Kromatografi Lapis Tipis. Indones Nat Res Pharm J. 2017;1(2):1–6.

Pujiati L, Sugiyanto S, Hasana AR. Uji Identifikasi Rhodamin B Pada Liptint Di Toko Kosmetik Kota X Menggunakan Metode Kromatografi Lapis Tipis. SENTRI J Ris Ilm. 2023;2(11):4554–64.

Mursyidah, Purwanti R, Christiandari H. Analisa Kualitatif Zat Warna Rhodamin B pada Lipstik dengan Metode Kromatografi Lapis Tipis. J Permata Indones. 2019;10(November).

Komarudin D, Fauziah S, Pramintari R. Analisis Rhodamin B Pada Sediaan Lipstik Dan Perona Mata Secara Kckt. J Ilm Kesehat. 2019;18(3):88–92.

Puspitasari L, Azizah K, Thalib A. Analisis Rhodamin B pada Lip Tint Menggunakan Metode Kromatografi Cair Kinerja Tinggi (KCKT). Sainstech Farma [Internet]. 2023;16(1):28–32. Available from: https://ejournal.istn.ac.id/index.php/saintechfarma/article/download/1495/990/

Fauziyah R, Hariningsih Y, Maritha V. ANALISIS RHODAMIN-B PADA LIP CREAM YANG BEREDAR DI Keywords : Rhodamine-B , lip cream , High Performance Liquid Chromatography ( HPLC ) Pendahuluan. Duta Pharma J. 2021;1(1).

Hiola F, Sy Pakaya M, Akuba J. Analisis Kadar Senyawa Rhodamin B Pada Sediaan Lipstik Menggunakan Metode Spektrofotometri UV-Vis. J Syifa Sci Clin Res. 2022;3(2):98–105.

Hipi D, Malaha A, Dunggio T. Analisis Kadar Zat Pewrna Rhodamin B Pada Pewarna Bibir Yang Beredar Di Pasar Minggu Kabupaten Gorontalo. J Ilm [Internet]. 2022;2(1):11–21. Available from: https://journals.ubmg.ac.id/index.php/JIAS/article/download/1074/315

Juliyanti J, Karimah U, Apriyani L. Deteksi Dan Kuantifikasi Rhodamin B Pada Produk Lipstik Tanpa Nomor Notifikasi Bpom Yang Beredar Di Pasar Malam Kecamatan Palaran Samarinda. J Sustain Transform. 2022;1(1):1–8.

Retnowati D, Rahmawati S, Hermansyah O, Slamet S. IDENTIFIKASI RHODAMIN B PADA LIPSTIK YANG BEREDAR DI KOTA BENGKULU DENGAN METODE SPEKTROFOTOMETRI UV-VISIBEL Program Studi D3 Farmasi FMIPA Universitas Bengkulu JP : Jurnal Pharmacopoeia PENDAHULUAN Kosmetik merupakan salah satu kebutuhan yang umum diguna. J Pharmacopoeia. 2024;3(1):24–32.

Bintang M. Biokimia Teknik Penelitian. Jakarta: Penerbit Erlangga; 2010.

Nurhayati R. Pengembangan Dan Validasi Metode Klt – Densitometri Untuk Penetapan Kadar Filantin Dalam Ekstrak Phyllanthus Niruri Menggunakan Desain Plackett - Burman Untuk Uji Robustness. 2020; Available from: http://lib.unair.ac.id

Muttaqin FZ, Yuliantini A, Fitriawati A, Asnawi A. PENETAPAN KADAR SENYAWA METAMPIRON DAN DIAZEPAM DALAM SEDIAAN KOMBINASI OBAT MENGGUNAKAN METODE KLT VIDEO DENSITOMETRI. PHARMACY. 2016;13(02):127–36.

Wulandari L. Kromatografi Lapis Tipis. Cetakan pe. Jember: PT. Taman Kampus Presindo; 2011.

Kusuma ASW, Ismanto RMH. Penggunaan Instrumen High-Performance Liquid Chromatography Sebagai Metode Penentuan Kadar Kapsaisin Pada Bumbu Masak Kemasan “Bumbu Marinade Ayam Special” Merek Sasa. J Farmaka. 2016;14(2):41–6.

Yusransyah RC, Maghfiroh, Rochmat A. Uji kesesuaian sistem kromatografi cair kinerja tinggi fase terbalik pada bahan baku parasetamol. Farmagazine. 2014;1(2):1–7.

Fajri MI. Validasi metode analisis identifikasi simultan Hidrokuinon dan Asam Retinoat secara UHPLC-PDA dalam sediaan semi solida. Erud Indones J Food Drug [Internet]. 2020;1(1):1–10. Available from: https://eruditio.pom.go.id/index.php/home/article/view/21

Siswanto A, Fudhol A, Nugroho AK, Martono S. Validasi Metode HPLC untuk Penetapan Aspirin dan Asam Salisilat dalam Plasma Kelinci (Lepus curpaeums) secara Simultan. J Kefarmasian Indones. 2016;6(2):68–78.

Fauziah S, Komarudin D, Dewi C. Identifikasi dan Penetapan Kadar Rhodamin B pada Eye Shadow secara Kromatografi Lapis Tipis dan Spektrofotometri Ultraviolet-Visible. J Ilm Kesehat. 2020;19(02):81–6.

Hadriyati A, Lestari L, Anggresani L. Analisis Rhodamin B dalam Bolu Kukus yang Beredar di Kota Jambi dengan Metode Spektrofotometri UV-Vis. J Farm Dan Ilmu Kefarmasian Indones. 2021;8(1):16.

Angraini N, Desmaniar P. Optimasi penggunaan High Performance Liquid Chromatography (HPLC) untuk analisis asam askorbat guna menunjang kegiatan Praktikum Bioteknologi Kelautan. J Penelit Sains. 2020;22(2):69.

Nurhidayati L, Sofiah S, Sumarny R, Caesar K. HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD VALIDATION OF α-MANGOSTIN ASSAY IN MANGOSTEEN (Garcinia mangostana L.) FRUIT RIND EXTRACT FORMULATED IN ORAL SOLUTION. ALCHEMY J Penelit Kim. 2015;11(1):38.

Astles G. Solving Common Errors in HPLC [Internet]. 2023. Available from: https://www.chromatographytoday.com/news/hplc-uhplc/31/international-labmate-ltd/solving-common-errors-in-hplc/59518

Tumanduk R, Massi MN, Agus R, Sarjana SP, Studi P, Biomedik I, et al. Analisis residu amoksisilin pada hepar dan ventrikulus ayam petelur di Pasar Tradisional Makassar. J Ilmu Alam dan Lingkung. 2023;14(2):20–8.

Warono D, Syamsudin. Unjuk Kerja Spektrofotometer Untuk Analisa Zat Aktif Ketoprofen. J Konversi 2. 2014;

Sari LV. Pengaruh Variasi Konsentrasi HCI Pada Pembuatan Nanosilika Berbasi Batu Apung. J Tek Kim. 2019;12:1–23.

Rohman A. Kromatografi Untuk Analisis. Cetakan I. Graha Ilmu; 2009.

WHO. The International Pharmacopeia. Edisi ke-empat. Electronic Version Geneva; 1992. 98 p.

Ramadhan SA, Musfiroh I. Review Artikel: Verifikasi Metode Analisis Obat. Farmaka. 2021;19:87–92.

Kruve A, Rebane R, Kipper K, Oldekop M, Evard H. Tutorial Review on Validation of Liquid Chromatography–Mass Spectrometry Methods: Part I. Anal Chim Acta. 2015;29–44.

Tetha E.S DA, Sugiarso K. S RD. Pebandingan Metode Analisa Kadar Besi antara Serimetri dan Spektrofotometer UV-Vis dengan Pengompleks 1,10- Fenantrolin. Akta Kim Indones. 2016;1(1):8.
Published
2024-06-30
How to Cite
Prihasti, N., Mulki, M., & Hidayat, M. N. (2024). Narrative Review: Parameter dalam Metode Analisis untuk Identifikasi Rhodamin B dalam Lipstik. Jurnal Sehat Mandiri, 19(1), 271-284. https://doi.org/https://doi.org/10.33761/jsm.v19i1.1385